Fully automated preoperative liver volumetry incorporating the anatomical location of the central hepatic vein.
Ontology highlight
ABSTRACT: The precise preoperative calculation of functional liver volumes is essential prior major liver resections, as well as for the evaluation of a suitable donor for living donor liver transplantation. The aim of this study was to develop a fully automated, reproducible, and quantitative 3D volumetry of the liver from standard CT examinations of the abdomen as part of routine clinical imaging. Therefore, an in-house dataset of 100 venous phase CT examinations for training and 30 venous phase ex-house CT examinations with a slice thickness of 5 mm for testing and validating were fully annotated with right and left liver lobe. Multi-Resolution U-Net 3D neural networks were employed for segmenting these liver regions. The Sørensen-Dice coefficient was greater than 0.9726 ± 0.0058, 0.9639 ± 0.0088
SUBMITTER: Koitka S
PROVIDER: S-EPMC9526715 | biostudies-literature | 2022 Oct
REPOSITORIES: biostudies-literature
ACCESS DATA