Unknown

Dataset Information

Reliability of monitoring acid-base and electrolyte parameters through circuit lines during regional citrate anticoagulation-continuous renal replacement therapy.


ABSTRACT:

Background

The current practice involves blood sampling from the circuit line to measure acid-base and electrolyte parameters during continuous renal replacement therapy (CRRT). However, there is limited evidence supporting its reliability due to the effects of anticoagulant mechanism and access recirculation associated with regional citrate anticoagulation (RCA).

Aim

To evaluate the reliability of monitoring acid-base and electrolyte parameters through circuit lines in regular and reversed connections during RCA-CRRT.

Study design

In this prospective cohort study, we included critically ill patients receiving RCA-CRRT via a double-lumen catheter. During the second hour after CRRT initiation, we collected blood samples to monitor acid-base and electrolyte parameters a

SUBMITTER: Wang F 

PROVIDER: S-EPMC9540182 | biostudies-literature | 2022 Sep

REPOSITORIES: biostudies-literature