ABSTRACT: Background
Blood products are frequently exposed to room temperature or higher for longer periods than permitted by policy. We aimed to investigate if this resulted in a measurable effect on common quality parameters and viscoelastic hemostatic function of cold stored CPDA-1 whole blood.Study design and methods
450 ml of whole blood from 16 O Rh(D) positive donors was collected in 63 ml of CPDA-1 and stored cold. Eights bags were exposed to five weekly 4-h long transient temperature changes to 28°C. Eight bags were stored continuously at 4°C as a control. Samples were collected at baseline on day 1, after the first cycle on day 1 and weekly before each subsequent cycle (day 7, 14, 21, 28 and 35). Hemolysis, hematological parameters, pH, glucose, lactate, potassium, thromboe