ABSTRACT: Background
T2 * anisotropy affects the clinical assessment of tendons (magic-angle artifact) and may be a source of T2 *-misinterpretation.Purpose
To analyze T2 *-anisotropy and T2 *-decay of Achilles and patellar tendons in vitro at microscopic resolution using a variable-echo-time (vTE) sequence.Study type
Prospective.Specimen
Four human Achilles and four patellar tendons.Field strength/sequence
A 7 T MR-microscopy; 3D-vTE spoiled-gradient-echo-sequence (T2 *-mapping).Assessment
All tendons were measured at 0° and 55° relative to B0 . Additional angles were measured for one Achilles and one patellar tendon for a total of 11 angles ranging from 0° to 90°. T2 *-decay