ABSTRACT: Purpose
Reflectance of retinal nerve fibre layer (RNFL) can contribute to detecting the presence of glaucomatous damage and defining its extent. As a step towards developing a normative database for RNFL reflectance, we assessed within-eye and between-subject variability for RNFL reflectance in healthy eyes.Methods
Vertical 30° × 15° volume scans at the optic disc were gathered using SD-OCT (Spectralis OCT) from people free of eye disease. Scans were gathered for both eyes of 30 younger adults (mean ± SD = 27 ± 3 years) and for one eye of 30 older adults (68 ± 8 years). Reflectance was quantified for each voxel as the depth-resolved attenuation coefficient (AC). Values for AC were extracted for four slabs (0-52, 24-52, 24-36 and 36-60 μm) and at depths from 24 to 60 μm below the inner limiting membrane (ILM) in 4 μm steps.Results
Between-subject and within-eye standard deviations (SDs) for the logarithm of AC were similar; median differences were 0.02-0.03 log unit across all four slabs and depths from 24 to 48 μm. Means for the logarithm of AC were higher for younger than older eyes by ~0.1 log unit; this age effect was not due to differences in the raw reflectance of the RNFL, but rather to age-related changes in reflectance of deeper retina affecting the calculation of AC.Conclusions
In both groups, within-eye variability in RNFL reflectance near the optic disc was similar to between-subject variability. A better understanding of within-eye variability would be useful for developing normative databases.
SUBMITTER: Cheung H
PROVIDER: S-EPMC9547838 | biostudies-literature | 2022 Nov
REPOSITORIES: biostudies-literature
Cheung Hin H Swanson William H WH King Brett J BJ
Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) 20220801 6
<h4>Purpose</h4>Reflectance of retinal nerve fibre layer (RNFL) can contribute to detecting the presence of glaucomatous damage and defining its extent. As a step towards developing a normative database for RNFL reflectance, we assessed within-eye and between-subject variability for RNFL reflectance in healthy eyes.<h4>Methods</h4>Vertical 30° × 15° volume scans at the optic disc were gathered using SD-OCT (Spectralis OCT) from people free of eye disease. Scans were gathered for both eyes of 30 ...[more]