Ontology highlight
ABSTRACT: Background
A newly designed intravenous patient-controlled analgesia (PCA) device with a dual-channel elastomeric infusion pump has been recently introduced. One channel is a continuous line with a constant flow rate basal infusion, while the other channel has an adjustable flow rate and bolus function and is labeled as a selector-bolus channel. This study compared dual and single-channel intravenous PCA in terms of clinical effect and quality of recovery.Methods
Eighty-four patients undergoing total laparoscopic hysterectomy were randomly allocated to a 1-channel group (n = 41) or a 2-channel group (n = 43). Only the selector-bolus channel was utilized, but the continuous channel was not utilized in the 1-channel group, but both channels were utilized in the 2-channel grou
SUBMITTER: Oh SK
PROVIDER: S-EPMC9555110 | biostudies-literature | 2022 Oct
REPOSITORIES: biostudies-literature