Unknown

Dataset Information

Design and experimental evaluation of a Venturi and Venturi-Vortex microbubble aeration system.


ABSTRACT: This work presents an experimental evaluation of a Venturi and Venturi-Vortex microbubble aeration system, taking as input variables the water-air flow ratio, water renewal time and area-volume ratio of the water tank. The aeration process response variables are defined in terms of oxygen transfer and aeration efficiency through the standard volumetric mass transfer coefficient (KLa20), standard oxygen transfer rate (SOTR), and standard aeration efficiency (SAE). Two methods of air injection were analyzed: 1. Air injection in the throat chamber of the Venturi generator; 2. air supplying in the suction side of the hydraulic pump of the aeration system. Experimental results indicate that the water renewal time variable (RT) is a statistically significant factor with res

SUBMITTER: De Oro Ochoa E 

PROVIDER: S-EPMC9557901 | biostudies-literature | 2022 Oct

REPOSITORIES: biostudies-literature