Impact of scanner variability on lymph node segmentation in computational pathology.
Ontology highlight
ABSTRACT: Computer-aided diagnostics in histopathology are based on the digitization of glass slides. However, heterogeneity between the images generated by different slide scanners can unfavorably affect the performance of computational algorithms. Here, we evaluate the impact of scanner variability on lymph node segmentation due to its clinical importance in colorectal cancer diagnosis. 100 slides containing 276 lymph nodes were digitized using 4 different slide scanners, and 50 of the lymph nodes containing metastatic cancer cells. These 400 scans were subsequently annotated by 2 experienced pathologists to precisely label lymph node boundary. Three different segmentation methods were then applied and compared: Hematoxylin-channel-based thresholding (HCT), Hematoxylin-based active contours (HAC),
SUBMITTER: Khan A
PROVIDER: S-EPMC9577043 | biostudies-literature | 2022
REPOSITORIES: biostudies-literature
ACCESS DATA