Unknown

Dataset Information

0

Adaptive optics in single objective inclined light sheet microscopy enables three-dimensional localization microscopy in adult Drosophila brains.


ABSTRACT: Single-molecule localization microscopy (SMLM) enables the high-resolution visualization of organelle structures and the precise localization of individual proteins. However, the expected resolution is not achieved in tissue as the imaging conditions deteriorate. Sample-induced aberrations distort the point spread function (PSF), and high background fluorescence decreases the localization precision. Here, we synergistically combine sensorless adaptive optics (AO), in-situ 3D-PSF calibration, and a single-objective lens inclined light sheet microscope (SOLEIL), termed (AO-SOLEIL), to mitigate deep tissue-induced deteriorations. We apply AO-SOLEIL on several dSTORM samples including brains of adult Drosophila. We observed a 2x improvement in the estimated axial localization precision with respect to widefield without aberration correction while we used synergistic solution. AO-SOLEIL enhances the overall imaging resolution and further facilitates the visualization of sub-cellular structures in tissue.

SUBMITTER: Hung ST 

PROVIDER: S-EPMC9583434 | biostudies-literature | 2022

REPOSITORIES: biostudies-literature

altmetric image

Publications

Adaptive optics in single objective inclined light sheet microscopy enables three-dimensional localization microscopy in adult <i>Drosophila</i> brains.

Hung Shih-Te ST   Llobet Rosell Arnau A   Jurriens Daphne D   Siemons Marijn M   Soloviev Oleg O   Kapitein Lukas C LC   Grußmayer Kristin K   Neukomm Lukas J LJ   Verhaegen Michel M   Smith Carlas C  

Frontiers in neuroscience 20221006


Single-molecule localization microscopy (SMLM) enables the high-resolution visualization of organelle structures and the precise localization of individual proteins. However, the expected resolution is not achieved in tissue as the imaging conditions deteriorate. Sample-induced aberrations distort the point spread function (PSF), and high background fluorescence decreases the localization precision. Here, we synergistically combine sensorless adaptive optics (AO), <i>in-situ</i> 3D-PSF calibrati  ...[more]

Similar Datasets

| S-EPMC8184833 | biostudies-literature
| S-EPMC10630144 | biostudies-literature
| S-EPMC10275380 | biostudies-literature
| S-EPMC3141032 | biostudies-literature
| S-EPMC6071422 | biostudies-literature
| S-EPMC11741161 | biostudies-literature
| S-EPMC7203252 | biostudies-literature
| S-EPMC3289054 | biostudies-other
| S-EPMC6825599 | biostudies-literature
| S-EPMC8149693 | biostudies-literature