Unknown

Dataset Information

0

Spontaneous Charging of Drops on Lubricant-Infused Surfaces.


ABSTRACT: When a drop of a polar liquid slides over a hydrophobic surface, it acquires a charge. As a result, the surface charges oppositely. For applications such as the generation of electric energy, lubricant-infused surfaces (LIS) may be important because they show a low friction for drops. However, slide electrification on LIS has not been studied yet. Here, slide electrification on lubricant-infused surfaces was studied by measuring the charge generated by series of water drops sliding down inclined surfaces. As LIS, we used PDMS-coated glass with micrometer-thick silicone oil films on top. For PDMS-coated glass without lubricant, the charge for the first drop is highest. Then it decreases and saturates at a steady state charge per drop. With lubricant, the drop charge starts from 0, then it increases and reaches a maximum charge per drop. Afterward, it decreases again before reaching its steady-state value. This dependency is not a unique phenomenon for lubricant-infused PDMS; it also occurs on lubricant-infused micropillar surfaces. We attribute this dependency of charge on drop numbers to a change in surface conductivity and depletion of lubricant. These findings are helpful for understanding the charge process and optimizing solid-liquid nanogenerator devices in applications.

SUBMITTER: Li S 

PROVIDER: S-EPMC9583601 | biostudies-literature | 2022 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Spontaneous Charging of Drops on Lubricant-Infused Surfaces.

Li Shuai S   Bista Pravash P   Weber Stefan A L SAL   Kappl Michael M   Butt Hans-Jürgen HJ  

Langmuir : the ACS journal of surfaces and colloids 20221003 41


When a drop of a polar liquid slides over a hydrophobic surface, it acquires a charge. As a result, the surface charges oppositely. For applications such as the generation of electric energy, lubricant-infused surfaces (LIS) may be important because they show a low friction for drops. However, slide electrification on LIS has not been studied yet. Here, slide electrification on lubricant-infused surfaces was studied by measuring the charge generated by series of water drops sliding down inclined  ...[more]

Similar Datasets

| S-EPMC7735743 | biostudies-literature
| S-EPMC8050781 | biostudies-literature
| S-EPMC6584047 | biostudies-literature
| S-EPMC8764024 | biostudies-literature
| S-EPMC6662098 | biostudies-literature
| S-EPMC11636059 | biostudies-literature
| S-EPMC5765152 | biostudies-literature
| S-EPMC6645152 | biostudies-literature
| S-EPMC10568014 | biostudies-literature
| S-EPMC11609279 | biostudies-literature