Effects of Rigid and Nonrigid Connections between the Miniscrew and Anchorage Tooth on Dynamics, Efficacy, and Adverse Effects of Maxillary Second Molar Protraction: A Finite Element Analysis


ABSTRACT:

Introduction

Direct, rigid indirect, and nonrigid indirect absolute anchorages using temporary anchorage devices (TADs, mini-implants/miniscrews) can provide promising opportunities for challenging, yet common, orthodontic tooth movements such as molar protraction. Rigid rectangular wire and ligature wire are the most common methods of attaching a tooth to a miniscrew in indirect anchorages. We aimed to provide a comparison of the rigidity of the connecting wire in terms of stress on the miniscrew, the anchorage loss, and the risk of root resorption using finite element analysis (FEA).

Methods

The maxillary right second molar was protracted into the proximal space at a 150 g load (1) using direct absolute anchorage with a tapered miniscrew implanted between the premolar

SUBMITTER: Mazhari M 

PROVIDER: S-EPMC9586811 | biostudies-literature | 2022 Jan