A Self-Regulated Microfluidic Device with Thermal Bubble Micropumps.
Ontology highlight
ABSTRACT: Currently, many microchips must rely on an external force (such as syringe pump, electro-hydrodynamic pump, and peristaltic pump, etc.) to control the solution in the microchannels, which probably adds manual operating errors, affects the accuracy of fluid manipulation, and enlarges the noise of signal. In addition, the reasonable integration of micropump and microchip remain the stumbling block for the commercialization of microfluidic technique. To solve those two problems, we designed and fabricated a thermal bubble micropump based on MEMS (micro-electro-mechanical systems) technique. Many parameters (voltage, pulse time, cycle delay time, etc.) affecting the performance of this micropump were explored in this work. The experimental results showed the flow rate of solution with the assi