Ontology highlight
ABSTRACT: Objectives
Recently, a newly designed short-type single-balloon enteroscope (SBE), SIF-H290S, has been developed with a smaller outer diameter and a longer working length than conventional colonoscopes. It has passive bending and high-force transmission, making insertion easier. However, it is difficult to perform rescue colonoscopy with an SBE after incomplete colonoscopy in the same session. Therefore, this study evaluated the feasibility of consecutive rescue colonoscopy using SIF-H290S without overtube after incomplete colonoscopy.Methods
This was a single-center retrospective study. We included 19 rescue colonoscopies (19 patients) with SIF-H290S without overtube performed by 11 endoscopists in the SIF group and 38 rescue colonoscopies (38 patients) using a small-calib
SUBMITTER: Ochiai Y
PROVIDER: S-EPMC9613409 | biostudies-literature | 2022
REPOSITORIES: biostudies-literature