Ontology highlight
ABSTRACT: Importance
Long-term follow-up after transcatheter aortic valve replacement (TAVR) is of interest given that longitudinal data on mortality and durability of transcatheter heart valves are limited. The REPRISE III (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Randomized Clinical Evaluation) randomized clinical trial compared the mechanically expanded Lotus valve with the self-expanding CoreValve/EvolutR TAVR platforms.Objective
To describe the final 5-year outcomes of the REPRISE III trial.Design, setting, and participants
This prespecified secondary analysis assessed the final 5-year clinical, functional, and echocardiographic outcomes of 912 patients from the REPRISE III trial, which was conducted at 5
SUBMITTER: Rizik DG
PROVIDER: S-EPMC9614584 | biostudies-literature | 2022 Oct
REPOSITORIES: biostudies-literature