Unknown

Dataset Information

0

Diagnostic Performance of Magnetic Resonance Enterography Disease Activity Indices Compared with a Histological Reference Standard for Adult Terminal Ileal Crohn's Disease: Experience from the METRIC Trial.


ABSTRACT:

Background and aims

The simplified magnetic resonance enterography [MRE] index of activity [sMARIA], London, and 'extended' London, scoring systems are widely used in Crohn's disease [CD] to assess disease activity, although validation studies have usually been single-centre, retrospective, and/or used few readers. Here, we evaluated these MRE indices within a prospective, multicentre, multireader, diagnostic accuracy trial.

Methods

A subset of participants [newly diagnosed or suspected of relapse] recruited to the METRIC trial with available terminal ileal [TI] biopsies was included. Using pre-specified thresholds, the sensitivity and specificity of sMARIA, London, and 'extended' London scores for active and severe [sMARIA] TI CD were calculated using different thresholds for the histological activity index [HAI].

Results

We studied 111 patients [median age 29 years, interquartile range 21-41, 75 newly diagnosed, 36 suspected relapse] from seven centres, of whom 22 had no active TI CD [HAI = 0], 39 mild [HAI = 1], 13 moderate [HAI = 2], and 37 severe CD activity [HAI = 3]. In total, 26 radiologists prospectively scored MRE datasets as per their usual clinical practice. Sensitivity and specificity for active disease [HAI >0] were 83% [95% confidence interval 74% to 90%] and 41% [23% to 61%] for sMARIA, 76% [67% to 84%] and 64% [43% to 80%] for the London score, and 81% [72% to 88%] and 41% [23% to 61%] for the 'extended' London score, respectively. The sMARIA had 84% [69-92%] sensitivity and 53% [41-64%] specificity for severe CD.

Conclusions

When tested at their proposed cut-offs in a real-world setting, sMARIA, London, and 'extended' London indices achieve high sensitivity for active TI disease against a histological reference standard, but specificity is low.

SUBMITTER: Kumar S 

PROVIDER: S-EPMC9624291 | biostudies-literature | 2022 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Diagnostic Performance of Magnetic Resonance Enterography Disease Activity Indices Compared with a Histological Reference Standard for Adult Terminal Ileal Crohn's Disease: Experience from the METRIC Trial.

Kumar Shankar S   Parry Thomas T   Mallett Sue S   Bhatnagar Gauraang G   Plumb Andrew A   Walsh Shaun S   Scott Nigel N   Tandon Ruchi R   Chong Heung H   du Parcq John J   Martinez Adrianna A   Moorghen Morgan M   Rodriguez-Justo Manuel M   Halligan Steve S   Taylor Stuart A SA  

Journal of Crohn's & colitis 20221101 10


<h4>Background and aims</h4>The simplified magnetic resonance enterography [MRE] index of activity [sMARIA], London, and 'extended' London, scoring systems are widely used in Crohn's disease [CD] to assess disease activity, although validation studies have usually been single-centre, retrospective, and/or used few readers. Here, we evaluated these MRE indices within a prospective, multicentre, multireader, diagnostic accuracy trial.<h4>Methods</h4>A subset of participants [newly diagnosed or sus  ...[more]

Similar Datasets

| S-EPMC10791915 | biostudies-literature
| S-EPMC11632055 | biostudies-literature
| S-EPMC4556376 | biostudies-literature
| S-EPMC6505095 | biostudies-literature
| S-EPMC4984327 | biostudies-literature
| S-EPMC9535152 | biostudies-literature
2015-10-01 | GSE62207 | GEO
| S-EPMC5946585 | biostudies-literature
| S-EPMC9248101 | biostudies-literature
| S-EPMC11542238 | biostudies-literature