Methodological considerations when measuring and analyzing auditory steady-state responses with multi-channel EEG.
Ontology highlight
ABSTRACT: The auditory steady-state response (ASSR) has been traditionally recorded with few electrodes and is often measured as the voltage difference between mastoid and vertex electrodes (vertical montage). As high-density EEG recording systems have gained popularity, multi-channel analysis methods have been developed to integrate the ASSR signal across channels. The phases of ASSR across electrodes can be affected by factors including the stimulus modulation rate and re-referencing strategy, which will in turn affect the estimated ASSR strength. To explore the relationship between the classical vertical-montage ASSR and whole-scalp ASSR, we applied these two techniques to the same data to estimate the strength of ASSRs evoked by tones with sinusoidal amplitude modulation rates of around 40, 100,
SUBMITTER: Lu H
PROVIDER: S-EPMC9647176 | biostudies-literature | 2022
REPOSITORIES: biostudies-literature
ACCESS DATA