CONVENTIONAL INTERNAL LIMITING MEMBRANE PEELING VERSUS INVERTED FLAP FOR SMALL-TO-MEDIUM IDIOPATHIC MACULAR HOLE: A Randomized Trial.


ABSTRACT:

Purpose

To compare conventional internal limiting membrane (ILM) peeling versus inverted flap technique in small-to-medium idiopathic macular hole.

Methods

Eyes with ≤400 μ m idiopathic macular holes were randomized into the conventional ILM peeling group (25 eyes) and inverted flap group (25 eyes). A 12-month follow-up was considered. Macular sensitivity (MS) change detected with MP-1 microperimetry was the primary outcome. Secondary outcomes included best-corrected visual acuity change, closure rate, anatomical findings on optical coherence tomography such as U-shape foveal contour, restoration of external limiting membrane, and ellipsoid zone.

Results

In both groups, MS improved throughout the follow-up. Final MS was greater in the conventional ILM peeling group compared with the inverted flap group, being 16.6 ± 2.3 dB versus 14.9 ± 2.9 dB, respectively ( P = 0.026). In both groups best-corrected visual acuity improved throughout the follow-up, with a final best-corrected visual acuity of 0.19 ± 0.14 logMar (20/31 Snellen) in the conventional ILM group and 0.22 ± 0.11 logMar (20/33 Snellen) in the inverted flap group ( P = 0.398). Anatomical hole closure was achieved in all cases. No difference in optical coherence tomography findings was shown between the two groups.

Conclusion

A better final MS was found in eyes undergoing conventional ILM peeling. Inverted flap technique has disadvantages compared with conventional peeling for the treatment of small-to-medium idiopathic macular holes.

SUBMITTER: Ventre L 

PROVIDER: S-EPMC9665942 | biostudies-literature | 2022 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

CONVENTIONAL INTERNAL LIMITING MEMBRANE PEELING VERSUS INVERTED FLAP FOR SMALL-TO-MEDIUM IDIOPATHIC MACULAR HOLE: A Randomized Trial.

Ventre Luca L   Fallico Matteo M   Longo Antonio A   Parisi Guglielmo G   Russo Andrea A   Bonfiglio Vincenza V   Marolo Paola P   Caselgrandi Paolo P   Avitabile Teresio T   Borrelli Enrico E   Reibaldi Michele M  

Retina (Philadelphia, Pa.) 20220906 12


<h4>Purpose</h4>To compare conventional internal limiting membrane (ILM) peeling versus inverted flap technique in small-to-medium idiopathic macular hole.<h4>Methods</h4>Eyes with ≤400 μ m idiopathic macular holes were randomized into the conventional ILM peeling group (25 eyes) and inverted flap group (25 eyes). A 12-month follow-up was considered. Macular sensitivity (MS) change detected with MP-1 microperimetry was the primary outcome. Secondary outcomes included best-corrected visual acuity  ...[more]

Similar Datasets

| S-EPMC8487370 | biostudies-literature
| S-EPMC6136763 | biostudies-literature
| S-EPMC10857606 | biostudies-literature
| S-EPMC8501065 | biostudies-literature
| S-EPMC7463360 | biostudies-literature
| S-EPMC10798096 | biostudies-literature
| S-EPMC7002743 | biostudies-literature
| S-EPMC9403290 | biostudies-literature
| S-EPMC9217943 | biostudies-literature
| S-EPMC8619774 | biostudies-literature