ABSTRACT: Background
Optimal implant placement in reverse total shoulder arthroplasty (rTSA) remains controversial. Specifically, the optimal glenoid inclination is unknown. Therefore, a cadaveric shoulder simulator with 3-dimentional human motion specific to rTSA was used to study joint contact and muscle forces as a function of glenoid component inclination.Methods
Eight human cadaver shoulders were tested before and after rTSA implantation. Scapular plane abduction kinematics from control subjects and those with rTSA drove a cadaveric shoulder simulator with 3-dimentional scapulothoracic and glenohumeral motion. Glenoid inclination varied from -20° to +20°. Outputs included compression, superior-inferior (S/I) shear, and anterior-posterior shear forces from a 6° of freedom load ce
SUBMITTER: Knighton TW
PROVIDER: S-EPMC9669184 | biostudies-literature | 2022 Dec