Reliability of respiratory event detection with continuous positive airway pressure in moderate to severe obstructive sleep apnea - comparison of polysomnography with a device-based analysis.


ABSTRACT:

Purpose

Monitored polysomnography (PSG) is considered the gold standard technique to diagnose obstructive sleep apnea (OSA) and titrate continuous positive airway pressure (CPAP), the accepted primary treatment method. Currently, the American Academy of Sleep Medicine (AASM) considers automatic PAP therapy initiation at home comparable to laboratory titration and recommends telemonitoring-guided interventions. Advanced CPAP devices evaluate and report the residual apnea-hypopnea index (AHI). However, in order to control the effectiveness of the prescribed therapy outside of a PSG setting, the automatic event detection must provide reliable data.

Methods

A CPAP titration was performed in the sleep laboratory by PSG in patients with OSA. The residual event indices detected by

SUBMITTER: Richter M 

PROVIDER: S-EPMC9669528 | biostudies-literature | 2023 Aug