ABSTRACT: Aim
Positive pressure ventilation via a facemask is critical in neonatal resuscitation, but frequently results in mask leak, obstruction, and inadequate respiratory support. This systematic review aimed to determine whether the display of respiratory function monitoring improved resuscitation or clinical outcomes.Methods
Randomized controlled trials comparing outcomes when respiratory function monitoring was displayed versus not displayed for newborns requiring positive pressure ventilation at birth were selected and from databases (last search August 2022), and assessed for risk of bias using Cochrane Risk of Bias Tools for randomized control trials. The study was registered in the Prospective Register of Systematic Reviews. Grading of Recommendations, Assessment, Developm