Optimization of the Design Configuration and Operation Strategy of Single-Pass Seawater Reverse Osmosis.


ABSTRACT: The numerical study was conducted to compare process performance depending on the pump type and process configuration. The daily monitoring data of seawater temperature and salinity offshore from Daesan, Republic of Korea was used to reflect the site-specific seawater conditions. An algorithm for reverse osmosis in constant permeate mode was developed to simulate the process in time-variant conditions. Two types of pumps with different maximum leachable efficiencies were employed to organize pump-train configuration: separated feed lines and common pressure center design. The results showed pump type and design configuration did not have a significant effect on process performance. The annual means of specific energy consumption (SEC) for every design configuration were under 2 kWh/

SUBMITTER: Lim SJ 

PROVIDER: S-EPMC9692277 | biostudies-literature | 2022 Nov

REPOSITORIES: biostudies-literature