Modelling acute antibody-mediated rejection of human kidney transplants using ex-vivo warm machine perfusion.


ABSTRACT:

Background

Transplant rejection is a major cause of graft loss and morbidity. Currently, no human models of antibody-mediated rejection (AMR) exist, limiting mechanistic investigation and organ-specific targeted therapy. Here, using 12 human kidneys and ex-vivo normothermic machine perfusion, we demonstrate phenotypes of AMR after addition of antibodies against either human HLA class I or blood group antigens (A, B), thus modelling clinical AMR that can follow HLA incompatible (HLAi) or blood group incompatible (ABOi) transplantation.

Methods

Discarded human kidneys with wide ranging demographics and cold ischaemia times (11-54 h) were perfused with red blood cells and fresh frozen plasma (FFP) as a source of complement/coagulation factors. For the HLAi model, 600 μg of W6/3

SUBMITTER: Chandak P 

PROVIDER: S-EPMC9699940 | biostudies-literature | 2022 Nov