Direct Optical Lithography Enabled Multispectral Colloidal Quantum-Dot Imagers from Ultraviolet to Short-Wave Infrared.


ABSTRACT: Complementary metal oxide semiconductor (CMOS) silicon sensors play a central role in optoelectronics with widespread applications from small cell phone cameras to large-format imagers for remote sensing. Despite numerous advantages, their sensing ranges are limited within the visible (0.4-0.7 μm) and near-infrared (0.8-1.1 μm) range , defined by their energy gaps (1.1 eV). However, below or above that spectral range, ultraviolet (UV) and short-wave infrared (SWIR) have been demonstrated in numerous applications such as fingerprint identification, night vision, and composition analysis. In this work, we demonstrate the implementation of multispectral broad-band CMOS-compatible imagers with UV-enhanced visible pixels and SWIR pixels by layer-by-layer direct optical lithography of colloidal quantum dots (CQDs). High-resolution single-color images and merged multispectral images were obtained by using one imager. The photoresponse nonuniformity (PRNU) is below 5% with a 0% dead pixel rate and room-temperature responsivities of 0.25 A/W at 300 nm, 0.4 A/W at 750 nm, and 0.25 A/W at 2.0 μm.

SUBMITTER: Zhang S 

PROVIDER: S-EPMC9706660 | biostudies-literature | 2022 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Direct Optical Lithography Enabled Multispectral Colloidal Quantum-Dot Imagers from Ultraviolet to Short-Wave Infrared.

Zhang Shuo S   Bi Cheng C   Tan Yimei Y   Luo Yuning Y   Liu Yanfei Y   Cao Jie J   Chen Menglu M   Hao Qun Q   Tang Xin X  

ACS nano 20221108 11


Complementary metal oxide semiconductor (CMOS) silicon sensors play a central role in optoelectronics with widespread applications from small cell phone cameras to large-format imagers for remote sensing. Despite numerous advantages, their sensing ranges are limited within the visible (0.4-0.7 μm) and near-infrared (0.8-1.1 μm) range , defined by their energy gaps (1.1 eV). However, below or above that spectral range, ultraviolet (UV) and short-wave infrared (SWIR) have been demonstrated in nume  ...[more]

Similar Datasets

| S-EPMC9189642 | biostudies-literature
| S-EPMC6509134 | biostudies-literature
| S-EPMC11600258 | biostudies-literature
| S-EPMC10602987 | biostudies-literature
| S-EPMC11014860 | biostudies-literature
| S-EPMC12279176 | biostudies-literature
| S-EPMC10657373 | biostudies-literature
| S-EPMC7020105 | biostudies-literature