Unknown

Dataset Information

Long-term evaluation of TTK Chitra™ heart valve prosthesis - a retrospective-prospective cohort study.


ABSTRACT:

Purpose

The TTK Chitra™ heart valve has more than 1,40,000 implantations so far, but no long-term data has been published. This study aims to provide long-term results of the valve.

Methodology

A cohort of 476 patients with implantations from January 2006 to December 2018 were followed up prospectively consisting of 104 aortic valve replacement (AVR), 87 double valve replacement (DVR), and 285 mitral valve replacement (MVR) patients. Total follow-up was 4079 patient-years (py) (AVR = 983, MVR = 2392, DVR = 704), being 96% complete.

Results

The results showed that actuarial survival at 15 years was 82.3% for AVR, 60.7% for MVR, and 52.2% for DVR. Freedom from all valve-related mortality and morbidity at 15 years was 73.8%, 64.8%, and 61.9% for AVR, MVR, and DVR, respec

SUBMITTER: Varma PK 

PROVIDER: S-EPMC9735205 | biostudies-literature | 2023 Jan

REPOSITORIES: biostudies-literature