ABSTRACT: Background
To report a case of a corneal endothelial ring after toric implantable collamer lens (TICL, V4C) implantation in the right eye of a patient.Case presentation
A 36-year-old woman with refractive errors of -8.00 DS/-2.00 DC * 8° in the right eye and - 6.50 DS/-1.75 DC * 177° in the left eye developed a corneal endothelial ring in the right eye on the first day after receiving TICLs implantation for treatment of high myopic astigmatism, which has not been previously reported as a complication of ICLs implantation. At 1 day postoperatively, the uncorrected distance visual acuity (UDVA) was 20/16, the intraocular pressure as measured by non-contact tonometry was 16.9 mmHg, and the vault as measured by anterior segment optical coherence tomography was 1238 μm. The eye