Unknown

Dataset Information

Carbon-ion radiotherapy boost with standard dose proton radiation for incomplete-resected high-grade glioma: a phase 1 study.


ABSTRACT:

Background

To investigate the maximal tolerated dose (MTD) of a carbon-ion radiotherapy (CIRT) boost prior to standard dose proton radiotherapy (PRT) for newly diagnosed glioblastoma (GBM) and anaplastic astrocytoma (AA) patients with residual lesion after resection.

Methods

In total, 18 patients with high-grade glioma (HGG) (16 with GBM and 2 with AA) were enrolled in a prospective 3×3 design phase 1 trial. We investigated four dose-levels of CIRT boost [9 (starting level), 12, 15, and 18 Gy relative biological effectiveness (RBE)] delivered in three equal fractions prior to the standard dose PRT (60 Gy RBE in 30 fractions). Concurrent temozolomide (TMZ) was not provided during the CIRT boost but was initiated on the first day of PRT. Acute and late toxicities were scored b

SUBMITTER: Qiu X 

PROVIDER: S-EPMC9761177 | biostudies-literature | 2022 Nov

REPOSITORIES: biostudies-literature