Improvements to the Rapid Detection of the Marine Pathogenic Bacterium, Vibrio harveyi, Using Loop-Mediated Isothermal Amplification (LAMP) in Combination with SYBR Green.
Ontology highlight
ABSTRACT: The common methods that are presently used to identify Vibrio harveyi include microscopic examination and biochemical, immunological and PCR-based assays. These methods require technical expertise, and can be time-consuming. A rapid method is required for the high-throughput screening of large number of samples. As such, we have developed a rapid, simple yet sensitive and specific detection method based on the use of the loop-mediated isothermal amplification (LAMP) of DNA. A set of six primers, i.e., two outer, two inner and two loop primers, was designed based on the in silico analysis of a large pool of 39 strains of the toxR gene sequence of V. harveyi. The addition of the loop primers decreased the reaction time of the LAMP by more than half. Furthermore, with the