Unknown

Dataset Information

0

Depth-Resolved Localization Microangiography in the NIR-II Window.


ABSTRACT: Detailed characterization of microvascular alterations requires high-resolution 3D imaging methods capable of providing both morphological and functional information. Existing optical microscopy tools are routinely used for microangiography, yet offer suboptimal trade-offs between the achievable field of view and spatial resolution with the intense light scattering in biological tissues further limiting the achievable penetration depth. Herein, a new approach for volumetric deep-tissue microangiography based on stereovision combined with super-resolution localization imaging is introduced that overcomes the spatial resolution limits imposed by light diffusion and optical diffraction in wide-field imaging configurations. The method capitalizes on localization and tracking of flowing fluorescent particles in the second near-infrared window (NIR-II, ≈1000-1700 nm), with the third (depth) dimension added by triangulation and stereo-matching of images acquired with two short-wave infrared cameras operating in a dual-view mode. The 3D imaging capability enabled with the proposed method facilitates a detailed visualization of microvascular networks and an accurate blood flow quantification. Experiments performed in tissue-mimicking phantoms demonstrate that high resolution is preserved up to a depth of 4 mm in a turbid medium. Transcranial microangiography of the entire murine cortex and penetrating vessels is further demonstrated at capillary level resolution.

SUBMITTER: Zhou Q 

PROVIDER: S-EPMC9811471 | biostudies-literature | 2022 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Depth-Resolved Localization Microangiography in the NIR-II Window.

Zhou Quanyu Q   Nozdriukhin Daniil D   Chen Zhenyue Z   Glandorf Lukas L   Hofmann Urs A T UAT   Reiss Michael M   Tang Lin L   Deán-Ben Xosé Luís XL   Razansky Daniel D  

Advanced science (Weinheim, Baden-Wurttemberg, Germany) 20221120


Detailed characterization of microvascular alterations requires high-resolution 3D imaging methods capable of providing both morphological and functional information. Existing optical microscopy tools are routinely used for microangiography, yet offer suboptimal trade-offs between the achievable field of view and spatial resolution with the intense light scattering in biological tissues further limiting the achievable penetration depth. Herein, a new approach for volumetric deep-tissue microangi  ...[more]

Similar Datasets

| S-EPMC3221710 | biostudies-other
| S-EPMC5679521 | biostudies-literature
| S-EPMC6137042 | biostudies-literature
| S-EPMC10275987 | biostudies-literature
| S-EPMC10704552 | biostudies-literature
| S-EPMC9272591 | biostudies-literature
| S-EPMC8372559 | biostudies-literature
| S-EPMC6485425 | biostudies-literature
| S-EPMC10170720 | biostudies-literature
| S-EPMC9044443 | biostudies-literature