Prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images.


ABSTRACT:

Purpose

The aim of this study was to evaluate the accuracy of prostate volume estimates calculated from the ellipsoid formula using the anteroposterior (AP) diameter measured on axial and sagittal images obtained through ultrasonography (US) and magnetic resonance imaging (MRI).

Methods

This retrospective study included 456 patients with transrectal US and MRI from two university hospitals. Two radiologists independently measured the prostate gland diameters on US and MRI: AP diameters on axial and sagittal images, transverse, and longitudinal diameters on midsagittal images. The volume estimates, volumeax and volumesag, were calculated from the ellipsoid formula by using the AP diameter on axial and sagittal images, respectively. The prostate volume extracted from MRI-based whole-gland segmentation was considered the gold standard. The intraclass correlation coefficient (ICC) was used to evaluate the inter-method agreement between volumeax and volumesag, and agreement with the gold standard. The Wilcoxon signedrank test was used to analyze the differences between the volume estimates and the gold standard.

Results

The prostate gland volume estimates showed excellent inter-method agreement, and excellent agreement with the gold standard (ICCs >0.9). Compared with the gold standard, the volume estimates were significantly larger on MRI and significantly smaller on US (P<0.001). The volume difference (segmented volume-volume estimate) was greater in patients with larger prostate glands, especially on US.

Conclusion

Volumeax and volumesag showed excellent inter-method agreement and excellent agreement with the gold standard on both US and MRI. However, prostate volume was overestimated on MRI and underestimated on US.

SUBMITTER: Yoon SY 

PROVIDER: S-EPMC9816709 | biostudies-literature | 2023 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Prostate gland volume estimation: anteroposterior diameters measured on axial versus sagittal ultrasonography and magnetic resonance images.

Youn Seo Yeon SY   Choi Moon Hyung MH   Lee Young Joon YJ   Grimm Robert R   von Busch Heinrich H   Han Dongyeob D   Son Yohan Y   Lou Bin B   Kamen Ali A  

Ultrasonography (Seoul, Korea) 20221024 1


<h4>Purpose</h4>The aim of this study was to evaluate the accuracy of prostate volume estimates calculated from the ellipsoid formula using the anteroposterior (AP) diameter measured on axial and sagittal images obtained through ultrasonography (US) and magnetic resonance imaging (MRI).<h4>Methods</h4>This retrospective study included 456 patients with transrectal US and MRI from two university hospitals. Two radiologists independently measured the prostate gland diameters on US and MRI: AP diam  ...[more]

Similar Datasets

| S-EPMC11913898 | biostudies-literature
| S-EPMC7335595 | biostudies-literature
2011-11-23 | E-GEOD-33899 | biostudies-arrayexpress
| S-EPMC10693454 | biostudies-literature
2011-11-23 | GSE33899 | GEO
| S-EPMC7333079 | biostudies-literature
| S-EPMC11219917 | biostudies-literature
| S-EPMC9526737 | biostudies-literature
| S-EPMC10481467 | biostudies-literature
| S-EPMC9643442 | biostudies-literature