Adsorption Kinetic Model Predicts and Improves Reliability of Electrochemical Serotonin Detection.


ABSTRACT: Serotonin (5-HT) is a neurotransmitter involved in many biophysiological processes in the brain and in the gastrointestinal tract. Electrochemical methods are commonly used to quantify 5-HT, but their reliability may suffer due to the time-dependent nature of adsorption-limited 5-HT detection, as well as electrode fouling over repeated measurements. Mathematical characterization and modeling of adsorption-based electrochemical signal generation would improve reliability of 5-HT measurement. Here, a model was developed to track 5-HT electrode adsorption and resulting current output by combining Langmuir adsorption kinetic equations and adsorption-limited electrochemical equations. 5-HT adsorption binding parameters were experimentally determined at a carbon-nanotube coated Au electrode: KD = 7 × 10-7 M, kon = 130 M-1 s-1, koff = 9.1 × 10-5 s-1. A computational model of 5-HT adsorption was then constructed, which could effectively predict 5-HT fouling over 50 measurements (R2 = 0.9947), as well as predict electrode responses over varying concentrations and measurement times. The model aided in optimizing the measurement of 5-HT secreted from a model enterochromaffin cell line-RIN14B-minimizing measurement time. The presented model simplified and improved the characterization of 5-HT detection at the selected electrode. This could be applied to many other adsorption-limited electrochemical analytes and electrode types, contributing to the improvement of application-specific modeling and optimization processes.

SUBMITTER: Chapin AA 

PROVIDER: S-EPMC9844352 | biostudies-literature | 2023 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Adsorption Kinetic Model Predicts and Improves Reliability of Electrochemical Serotonin Detection.

Chapin Ashley Augustiny AA   Han Jinjing J   Ghodssi Reza R  

Methods and protocols 20230109 1


Serotonin (5-HT) is a neurotransmitter involved in many biophysiological processes in the brain and in the gastrointestinal tract. Electrochemical methods are commonly used to quantify 5-HT, but their reliability may suffer due to the time-dependent nature of adsorption-limited 5-HT detection, as well as electrode fouling over repeated measurements. Mathematical characterization and modeling of adsorption-based electrochemical signal generation would improve reliability of 5-HT measurement. Here  ...[more]

Similar Datasets

| S-EPMC8924176 | biostudies-literature
| S-EPMC10669129 | biostudies-literature
| S-EPMC10527390 | biostudies-literature
| S-EPMC8741178 | biostudies-literature
| S-EPMC3656761 | biostudies-other
| S-EPMC11358574 | biostudies-literature
| S-EPMC4802304 | biostudies-literature
| S-EPMC5373521 | biostudies-literature
| S-EPMC4483307 | biostudies-literature
| S-EPMC5377509 | biostudies-literature