Unknown

Dataset Information

0

A simple marking system for accurate intraoperative monitoring and adjustment of cyclotorsion strabismus surgery.


ABSTRACT: Ocular cyclotorsion is treatable only with surgery. The surgical procedure must be tailored individually to the specific etiologies causing the horizontal and vertical strabismus and its torsional components. An adjustable surgical approach is often used for postoperative or intraoperative adjustments. However, the methods currently used have some limitations. In this study, we propose a simple intraoperative marking system for all cyclotorsion correction surgery. The proposed marking system used three sets of surface markers: external horizontal markings, ocular horizontal markings, and surgical torsion markings, drawn in sequence. We retrospectively analyzed the surgical results using this novel marking system in this single-center, single-surgeon study. Fifteen patients with cyclotorsion who underwent treatment using the proposed marking system as an intraoperative aid between August 2019 and August 2021 were included. The medical charts were thoroughly reviewed, and the pre-and postoperative subjective and objective cyclotorsion were analyzed. Among the study subjects (10 males, 5 females; age range: 6-89 years), 13 had excyclotorsion and 2 incyclotorsion. Preoperative mean net subjective cyclotorsion measured by the double Maddox rod (DMR) test was 6.0° (standard deviation: 10.8°) and mean net disc-to-fovea angle (DFA) was 20.23° (13.21°). The postoperative net DMR and DFA were 0.2° (2.1°) and 14.09° (5.97°), respectively. The mean absolute net DMR and DFA being treated were 9.8° (4.8°) and 9.76° (4.61°). Overall, the proposed intraoperative marking system is a simple and quantitative method to assess, monitor, and adjust the torsional aspect for all strabismus surgeries.

SUBMITTER: Lee LC 

PROVIDER: S-EPMC9853205 | biostudies-literature | 2022

REPOSITORIES: biostudies-literature

altmetric image

Publications

A simple marking system for accurate intraoperative monitoring and adjustment of cyclotorsion strabismus surgery.

Lee Lung-Chi LC   Chang Hsu-Chieh HC   Chen Yi-Hao YH   Chien Ke-Hung KH  

Frontiers in medicine 20230106


Ocular cyclotorsion is treatable only with surgery. The surgical procedure must be tailored individually to the specific etiologies causing the horizontal and vertical strabismus and its torsional components. An adjustable surgical approach is often used for postoperative or intraoperative adjustments. However, the methods currently used have some limitations. In this study, we propose a simple intraoperative marking system for all cyclotorsion correction surgery. The proposed marking system use  ...[more]

Similar Datasets

| S-EPMC8816859 | biostudies-literature
| S-EPMC6543922 | biostudies-literature
| S-EPMC9600581 | biostudies-literature
| S-EPMC9250602 | biostudies-literature
| S-EPMC12420727 | biostudies-literature
2007-11-19 | GSE6381 | GEO
2022-10-04 | GSE197144 | GEO