ABSTRACT: Purpose
To develop a new myelin water imaging (MWI) technique using a short-TR adiabatic inversion-recovery (STAIR) sequence on a clinical 3T MR scanner.Methods
Myelin water (MW) in the brain has both a much shorter T1 and a much shorter T2 * than intracellular/extracellular water. A STAIR sequence with a short TR was designed to efficiently suppress long T1 signals from intracellular/extracellular water, and therefore allow selective imaging of MW, which has a much shorter T1 . Numerical simulation and phantom studies were performed to investigate the effectiveness of long T1 signal suppression. TheT2 * in white matter (WM) was measured with STAIR and compared with T2 * measured with a conventiona