Validation and application of a quantitative liquid chromatography tandem mass spectrometry assay for the analysis of rifapentine and 25-O-desacetyl rifapentine in human milk.
Ontology highlight
ABSTRACT: A robust analytical method based on liquid chromatography coupled to tandem mass spectrometry was developed and validated to quantify rifapentine and 25-O-desacetyl rifapentine in human breast milk to aid in determining the breastfed infant risk to the excreted drug in human milk. Samples were extracted by a combination of protein precipitation and solid phase extraction using rifampicin-d3 as an internal standard. An Agilent® Poroshell 120 EC-C18 (4.6 mm × 50 mm, 2.7 µm) column was used for chromatographic separation employing an isocratic mobile phase consisting of acetonitrile: methanol: 0.1% formic acid (55/5/40, v/v/v) at a flow rate of 450 µL/min, and with a total run time of four minutes. Mass detection was on an AB Sciex API 4000 mass spectrometer using electrospray ionization in t
SUBMITTER: Mkhize B
PROVIDER: S-EPMC9871952 | biostudies-literature | 2022 Jun
REPOSITORIES: biostudies-literature
ACCESS DATA