Bimatoprost Implant Biodegradation in the Phase 3, Randomized, 20-Month ARTEMIS Studies.
Ontology highlight
ABSTRACT: Purpose: To evaluate the time course of biodegradation of an intracameral, biodegradable, sustained-release bimatoprost implant that lowers intraocular pressure without the need for daily eye drops. Methods: In 2 identically designed, randomized, phase 3 clinical trials, adults with open-angle glaucoma or ocular hypertension and open iridocorneal angles inferiorly in the study eye were administered 10- or 15-μg bimatoprost implant (day 1 and weeks 16 and 32) or twice-daily topical timolol 0.5%. Implants were assessed on gonioscopy throughout the studies. Investigators reported whether implants were visible, estimated the size of visible implants relative to their initial size at implantation, and reported the implant location. Data for 10-μg implant placed on da
SUBMITTER: Weinreb RN
PROVIDER: S-EPMC9885540 | biostudies-literature | 2023 Jan-Feb
REPOSITORIES: biostudies-literature