Corneal biomechanical characteristics following small incision lenticule extraction for myopia and astigmatism with 3 different cap thicknesses.


ABSTRACT:

Background

The design of cap thickness for small incision lenticule extraction (SMILE) plays a role in post-laser vision correction (post-LVC) corneal biomechanics. This study aimed to compare the corneal biomechanical characteristics following SMILE with different cap thicknesses of 110 μm, 120 μm, and 130 μm for myopia and myopic astigmatism correction.

Methods

Seventy-five patients (146 eyes) who underwent SMILE with designed cap thickness of 110 μm, 120 μm, and 130 μm were recruited at the Eye Center of Beijing Tongren Hospital between August 2020 and November 2021. Visual acuity, refraction, and corneal biomechanical parameters were measured preoperatively, 1 week and 1, 3, 6 months postoperatively. One-way analysis of variances (ANOVA) with Bonferroni correction or Kru