Low field slice-selective ZTE imaging of ultra-short [Formula: see text] tissues based on spin-locking.


ABSTRACT: Magnetic Resonance Imaging of hard biological tissues is very challenging due to small proton abundance and ultra-short [Formula: see text] decay times, especially at low magnetic fields, where sample magnetization is weak. While several pulse sequences, such as Ultra-short Echo Time (UTE), Zero Echo Time (ZTE) and SWeep Imaging with Fourier Transformation (SWIFT), have been developed to cope with ultra-short lived MR signals, only the latter two hold promise of imaging tissues with sub-millisecond [Formula: see text] times at low fields. All these sequences are intrinsically volumetric, thus 3D, because standard slice selection using a long soft radio-frequency pulse is incompatible with ultra-short lived signals. The exception is UTE, where double half pulses can perform slice selection, although at the cost of doubling the acquisition time. Here we demonstrate that spin-locking is a versatile and robust method for slice selection for ultra-short lived signals, and present three ways of combining this pulse sequence with ZTE imaging of the selected slice. With these tools, we demonstrate slice-selected 2D ex vivo imaging of the hardest tissues in the body at low field (260 mT) within clinically acceptable times.

SUBMITTER: Borreguero J 

PROVIDER: S-EPMC9886919 | biostudies-literature | 2023 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Low field slice-selective ZTE imaging of ultra-short [Formula: see text] tissues based on spin-locking.

Borreguero Jose J   Galve Fernando F   Algarín José M JM   Benlloch José M JM   Alonso Joseba J  

Scientific reports 20230130 1


Magnetic Resonance Imaging of hard biological tissues is very challenging due to small proton abundance and ultra-short [Formula: see text] decay times, especially at low magnetic fields, where sample magnetization is weak. While several pulse sequences, such as Ultra-short Echo Time (UTE), Zero Echo Time (ZTE) and SWeep Imaging with Fourier Transformation (SWIFT), have been developed to cope with ultra-short lived MR signals, only the latter two hold promise of imaging tissues with sub-millisec  ...[more]

Similar Datasets

| S-EPMC8494935 | biostudies-literature
| S-EPMC4410410 | biostudies-other
| S-EPMC9701793 | biostudies-literature
| S-EPMC10394051 | biostudies-literature
| S-EPMC8595440 | biostudies-literature
| S-EPMC10539531 | biostudies-literature
| S-EPMC10524110 | biostudies-literature
| S-EPMC8671446 | biostudies-literature
| S-EPMC4424041 | biostudies-other
| S-EPMC7498615 | biostudies-literature