ABSTRACT: Purpose
Comparison of the performance of high-resolution susceptibility weighted imaging with standard MR sequences and MR venography to identify cortical vein clots.Methods
A retrospective review of 51 consecutive cases of cerebral venous thrombosis and 27 controls was performed with independent analysis of all MR sequences. Reference standard was obtained with consensus in a separate session by reviewing all MR sequences together.Results
Cortical vein clots were observed in 30 cases including 9 males and 21 females in the age range of 1 month to 70 years (Mean 34.9 ± 20.2 years). Sensitivity, specificity, negative predictive value, positive predictive value and accuracy of susceptibility weighted imaging for the identification of cortical vein clots were 0.93, 1.0