Ontology highlight
ABSTRACT: Background
Pulse pressure variation (PPV) has been widely used in hemodynamic assessment. Nevertheless, PPV is limited in low tidal volume ventilation. We conducted this systematic review and meta-analysis to evaluate whether the tidal volume challenge (TVC) could improve the feasibility of PPV in patients ventilated at low tidal volumes.Methods
PubMed, Embase and Cochrane Library inception to October 2022 were screened for diagnostic researches relevant to the predictability of PPV change after TVC in low tidal volume ventilatory patients. Summary receiving operating characteristic curve (SROC), pooled sensitivity and specificity were calculated. Subgroup analyses were conducted for possible influential factors of TVC.Results
Ten studies with a total of 429 patient
SUBMITTER: Wang X
PROVIDER: S-EPMC9893685 | biostudies-literature | 2023 Feb
REPOSITORIES: biostudies-literature