Unknown

Dataset Information

Thoracic Endovascular Aortic Repair with Supra-Aortic Trunk Revascularization is Associated with Increased Risk of Periprocedural Ischemic Stroke.


ABSTRACT:

Background

Ischemic stroke is a devastating complication of thoracic endovascular aortic repair (TEVAR). This risk may be higher in more proximal aneurysms that require arch manipulation. The purpose of this study is to (1) describe 30-day stroke and death rates in patients undergoing TEVAR, (2) compare stroke rates in patients undergoing TEVAR for arch versus descending aneurysm pathology, and (3) identify predictive factors associated with stroke after TEVAR.

Methods

The Vascular Quality Initiative registry was queried (2015-2021) for TEVAR procedures performed for degenerative aneurysms. Our primary outcomes were any stroke or death at 30 days. Patient-, procedure-, and hospital-level predictors of stroke were assessed using multivariable Poisson regression.

Results

SUBMITTER: Li RD 

PROVIDER: S-EPMC9901212 | biostudies-literature | 2022 Nov