Unknown

Dataset Information

0

In Vitro Measurement and Mathematical Modeling of Thermally-Induced Injury in Pancreatic Cancer Cells.


ABSTRACT: Thermal therapies are under investigation as part of multi-modality strategies for the treatment of pancreatic cancer. In the present study, we determined the kinetics of thermal injury to pancreatic cancer cells in vitro and evaluated predictive models for thermal injury. Cell viability was measured in two murine pancreatic cancer cell lines (KPC, Pan02) and a normal fibroblast (STO) cell line following in vitro heating in the range 42.5-50 °C for 3-60 min. Based on measured viability data, the kinetic parameters of thermal injury were used to predict the extent of heat-induced damage. Of the three thermal injury models considered in this study, the Arrhenius model with time delay provided the most accurate prediction (root mean square error = 8.48%) for all cell lines. Pan02 and STO cells were the most resistant and susceptible to hyperthermia treatments, respectively. The presented data may contribute to studies investigating the use of thermal therapies as part of pancreatic cancer treatment strategies and inform the design of treatment planning strategies.

SUBMITTER: Chamani F 

PROVIDER: S-EPMC9913239 | biostudies-literature | 2023 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

In Vitro Measurement and Mathematical Modeling of Thermally-Induced Injury in Pancreatic Cancer Cells.

Chamani Faraz F   Pyle Marla M MM   Shrestha Tej B TB   Sebek Jan J   Bossmann Stefan H SH   Basel Matthew T MT   Sheth Rahul A RA   Prakash Punit P  

Cancers 20230121 3


Thermal therapies are under investigation as part of multi-modality strategies for the treatment of pancreatic cancer. In the present study, we determined the kinetics of thermal injury to pancreatic cancer cells in vitro and evaluated predictive models for thermal injury. Cell viability was measured in two murine pancreatic cancer cell lines (KPC, Pan02) and a normal fibroblast (STO) cell line following in vitro heating in the range 42.5-50 °C for 3-60 min. Based on measured viability data, the  ...[more]

Similar Datasets

| S-EPMC4583820 | biostudies-literature
2016-03-16 | E-GEOD-79208 | biostudies-arrayexpress
| S-EPMC10914268 | biostudies-literature
2016-03-16 | GSE79208 | GEO
| S-EPMC8277755 | biostudies-literature
| S-EPMC4772546 | biostudies-literature
| S-EPMC5431931 | biostudies-literature
| S-EPMC5206284 | biostudies-literature
| S-EPMC8019197 | biostudies-literature
| S-EPMC6354781 | biostudies-literature