Unknown

Dataset Information

0

A fully-enclosed prototype 'pen' for rapid detection of SARS-CoV-2 based on RT-RPA with dipstick assay at point-of-care testing.


ABSTRACT: A fully-enclosed prototype 'pen' for rapid detection of SARS-CoV-2 based on reverse transcriptase isothermal recombinase polymerase amplification (RT-RPA) with dipstick assay was developed. The integrated handheld device, consisting of amplification, detection and sealing modules, was developed to perform rapid nucleic acid amplification and detection under a fully enclosed condition. After RT-RPA amplification with a metal bath or a normal PCR instrument, the amplicons were mixed with dilution buffer prior to being detected on a lateral flow strip. To avoid aerosol contamination causing false-positive, from amplification to final detection, the detection 'pen' had been enclosed to isolate from the environment. With colloidal gold strip-based detection, the detection results could be directly observed by eyes. By cooperating with other inexpensive and rapid methods for POC nucleic acid extraction, the developed 'pen' could detect COVID-19 or other infectious diseases in a convenient, simple and reliable way.

SUBMITTER: Fu Q 

PROVIDER: S-EPMC9934921 | biostudies-literature | 2023 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

A fully-enclosed prototype 'pen' for rapid detection of SARS-CoV-2 based on RT-RPA with dipstick assay at point-of-care testing.

Fu Qiang Q   Tu Yunping Y   Cheng Lun L   Zhang Lulu L   Qiu Xianbo X  

Sensors and actuators. B, Chemical 20230217


A fully-enclosed prototype 'pen' for rapid detection of SARS-CoV-2 based on reverse transcriptase isothermal recombinase polymerase amplification (RT-RPA) with dipstick assay was developed. The integrated handheld device, consisting of amplification, detection and sealing modules, was developed to perform rapid nucleic acid amplification and detection under a fully enclosed condition. After RT-RPA amplification with a metal bath or a normal PCR instrument, the amplicons were mixed with dilution  ...[more]

Similar Datasets

| S-EPMC8815761 | biostudies-literature
| S-EPMC4818709 | biostudies-literature
| S-EPMC11309845 | biostudies-literature
| S-EPMC9049791 | biostudies-literature
| S-EPMC10640725 | biostudies-literature
| S-EPMC10576173 | biostudies-literature
| S-EPMC9884195 | biostudies-literature
| S-EPMC7903145 | biostudies-literature
| S-EPMC7773598 | biostudies-literature
| S-EPMC9141210 | biostudies-literature