Unknown

Dataset Information

Fully-automated deep learning-based flow quantification of 2D CINE phase contrast MRI.


ABSTRACT:

Objectives

Time-resolved, 2D-phase-contrast MRI (2D-CINE-PC-MRI) enables in vivo blood flow analysis. However, accurate vessel contour delineation (VCD) is required to achieve reliable results. We sought to evaluate manual analysis (MA) compared to the performance of a deep learning (DL) application for fully-automated VCD and flow quantification and corrected semi-automated analysis (corSAA).

Methods

We included 97 consecutive patients (age = 52.9 ± 16 years, 41 female) with 2D-CINE-PC-MRI imaging on 1.5T MRI systems at sinotubular junction (STJ), and 28/97 also received 2D-CINE-PC at main pulmonary artery (PA). A cardiovascular radiologist performed MA (reference) and corSAA (built-in tool) in commercial software for all cardiac time frames (median: 20, total contours per

SUBMITTER: Pradella M 

PROVIDER: S-EPMC9935671 | biostudies-literature | 2023 Mar

REPOSITORIES: biostudies-literature