Is the Verification Phase a Suitable Criterion for the Determination of Maximum Oxygen Uptake in Patients with Heart Failure and Reduced Ejection Fraction? A Validation Study.


ABSTRACT: The verification phase (VP) has been proposed as an alternative to the traditional criteria used for the determination of the maximum oxygen uptake (VO2 max) in several populations. Nonetheless, its validity in patients with heart failure with reduced ejection fraction (HFrEF) remains unclear. Therefore, the aim of this study was to analyse whether the VP is a safe and suitable method to determine the VO2 max in patients with HFrEF. Adult male and female patients with HFrEF performed a ramp-incremental phase (IP), followed by a submaximal constant VP (i.e., 95% of the maximal workload during the IP) on a cycle ergometer. A 5-min active recovery period (i.e., 10 W) was performed between the two exercise phases. Group (i.e., median values) and individual comparisons wer

SUBMITTER: Manresa-Rocamora A 

PROVIDER: S-EPMC9956911 | biostudies-literature | 2023 Feb

REPOSITORIES: biostudies-literature