Unknown

Dataset Information

0

Compliance with Electronic Patient Reported Outcome Measure System Data Collection Is 51% Two-years After Shoulder Arthroscopy.


ABSTRACT:

Objective

To determine patient compliance in completing electronic patient-reported outcome measures (PROMs) following arthroscopic shoulder surgery and identify risk factors for noncompliance.

Methods

A retrospective review of compliance data was performed for patients who underwent arthroscopic shoulder surgery by a single surgeon in a private practice setting from June 2017 to June 2019. All patients were enrolled in Surgical Outcomes System (Arthrex) as a part of routine clinical care, and outcome reporting was integrated into our practice electronic medical record. Patient compliance with PROMs was calculated at preoperative, three-month, 6-month, 1-year, and 2-year follow-up time points. Compliance was defined as a complete patient response to each assigned outcome module in the database over time. Logistic regression for compliance at the one-year timepoint was performed to assess for factors associated with survey compliance.

Results

Compliance with PROMs was highest preoperatively (91.1%) and decreased at each subsequent time point. The largest decrease in compliance with PROMs occurred between the preoperative and 3-month follow-up time points. Compliance was 58% at 1 year and 51% at 2 years after surgery. Overall, 36% of patients were compliant at all individual time points. There were no significant predictors of compliance with regard to age, sex, race, ethnicity, or procedure.

Conclusions

Patient compliance with PROMs decreased over time with the lowest percentage of patients completing electronic surveys at the traditional 2-year follow-up for shoulder arthroscopy. In this study, basic demographic factors were not predictive of patient compliance with PROMs.

Clinical relevance

PROMs are commonly collected after arthroscopic shoulder surgery; however, low patient compliance may affect their utility in research and clinical practice.

SUBMITTER: Smith MD 

PROVIDER: S-EPMC9971883 | biostudies-literature | 2023 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Compliance with Electronic Patient Reported Outcome Measure System Data Collection Is 51% Two-years After Shoulder Arthroscopy.

Smith Matthew D MD   Madden Ryan N RN   Proffitt Michael J MJ   Hartzler Robert U RU  

Arthroscopy, sports medicine, and rehabilitation 20221214 1


<h4>Objective</h4>To determine patient compliance in completing electronic patient-reported outcome measures (PROMs) following arthroscopic shoulder surgery and identify risk factors for noncompliance.<h4>Methods</h4>A retrospective review of compliance data was performed for patients who underwent arthroscopic shoulder surgery by a single surgeon in a private practice setting from June 2017 to June 2019. All patients were enrolled in Surgical Outcomes System (Arthrex) as a part of routine clini  ...[more]

Similar Datasets

| S-EPMC8915447 | biostudies-literature
| S-EPMC9447377 | biostudies-literature
| S-EPMC6620474 | biostudies-literature
| S-EPMC11494241 | biostudies-literature
| S-EPMC6388703 | biostudies-literature
| S-EPMC8686465 | biostudies-literature
| S-EPMC6551420 | biostudies-literature
| S-EPMC3882714 | biostudies-literature
| S-EPMC7060104 | biostudies-literature