Persistent Air Bubble Sequestered at the Silicone Oil–Silicone Intraocular Lens Interface as a Cause of Reversible Visual Distortion


ABSTRACT:

Purpose:

To report a novel cause of post-operative reversible visual distortion due to a persistent air bubble sequestered at the intraocular lens (IOL)–silicone oil interface.

Methods:

Two cases of persistent, sequestered air at the IOL-silicone oil interface were identified and reviewed. Relevant clinical information, images and surgical videos were analyzed and described.

Results:

Resolution of the visual distortion was achieved in both cases after silicone oil removal.

Conclusions:

Silicone oil adhesion to the posterior surface of silicone IOLs is a known cause of visual degradation. The IOL-silicone oil interface can sequester air that persists and causes visual distortion until the oil is removed. We report the first cases, to our knowledge, of rev