Unknown

Dataset Information

0

Establishing the Validity of Compressed Sensing Diffusion Spectrum Imaging.


ABSTRACT: Diffusion Spectrum Imaging (DSI) using dense Cartesian sampling of q-space has been shown to provide important advantages for modeling complex white matter architecture. However, its adoption has been limited by the lengthy acquisition time required. Sparser sampling of q-space combined with compressed sensing (CS) reconstruction techniques has been proposed as a way to reduce the scan time of DSI acquisitions. However prior studies have mainly evaluated CS-DSI in post-mortem or non-human data. At present, the capacity for CS-DSI to provide accurate and reliable measures of white matter anatomy and microstructure in the living human brain remains unclear. We evaluated the accuracy and inter-scan reliability of 6 different CS-DSI schemes that provided up to 80% reductions in scan time compared to a full DSI scheme. We capitalized on a dataset of twenty-six participants who were scanned over eight independent sessions using a full DSI scheme. From this full DSI scheme, we subsampled images to create a range of CS-DSI images. This allowed us to compare the accuracy and inter-scan reliability of derived measures of white matter structure (bundle segmentation, voxel-wise scalar maps) produced by the CS-DSI and the full DSI schemes. We found that CS-DSI estimates of both bundle segmentations and voxel-wise scalars were nearly as accurate and reliable as those generated by the full DSI scheme. Moreover, we found that the accuracy and reliability of CS-DSI was higher in white matter bundles that were more reliably segmented by the full DSI scheme. As a final step, we replicated the accuracy of CS-DSI in a prospectively acquired dataset (n=20, scanned once). Together, these results illustrate the utility of CS-DSI for reliably delineating in vivo white matter architecture in a fraction of the scan time, underscoring its promise for both clinical and research applications.

SUBMITTER: Radhakrishnan H 

PROVIDER: S-EPMC9980087 | biostudies-literature | 2023 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications


Diffusion Spectrum Imaging (DSI) using dense Cartesian sampling of <i>q</i>-space has been shown to provide important advantages for modeling complex white matter architecture. However, its adoption has been limited by the lengthy acquisition time required. Sparser sampling of <i>q</i>-space combined with compressed sensing (CS) reconstruction techniques has been proposed as a way to reduce the scan time of DSI acquisitions. However prior studies have mainly evaluated CS-DSI in post-mortem or no  ...[more]

Similar Datasets

| S-EPMC10960521 | biostudies-literature
| S-EPMC10272537 | biostudies-literature
| S-EPMC2909438 | biostudies-literature
| S-EPMC8355028 | biostudies-literature
| S-EPMC4945498 | biostudies-literature
| S-EPMC12748953 | biostudies-literature
| S-EPMC7826382 | biostudies-literature