Evaluating the accuracy of CAD/CAM optimized stones compared to conventional type IV stones.


ABSTRACT: This study compared the accuracy (trueness and precision) of stone models fabricated using two brands of CAD/CAM optimized stones Cerec Stone (BC) and Elite Master (EM), and a conventional type IV stone Elite Rock Fast (ERF). 30 conventional Type IV and scannable stone complete-arch models were scanned with a blue LED extraoral scanner, and root mean square values were obtained. 6 abutments were used in complete-arch models. The digital models were compared with the master model to evaluate their trueness using model superimposition with Geomagic software. Precision was determined for each case by superimposing combinations of the 10 datasets in each group. The point cloud density of each model was calculated with MeshLab software. Kruskal-Wallis and Mann-Whitney non-parametric tests were