Investigating thrombin-loaded fibrin in whole blood clot microfluidic assay via fluorogenic peptide.


ABSTRACT: During clotting under flow, thrombin rapidly generates fibrin, whereas fibrin potently sequesters thrombin. This co-regulation was studied using microfluidic whole blood clotting on collagen/tissue factor, followed by buffer wash, and a start/stop cycling flow assay using the thrombin fluorogenic substrate, Boc-Val-Pro-Arg-AMC. After 3 min of clotting (100 s-1) and 5 min of buffer wash, non-elutable thrombin activity was easily detected during cycles of flow cessation. Non-elutable thrombin was similarly detected in plasma clots or arterial whole blood clots (1000 s-1). This thrombin activity was ablated by Phe-Pro-Arg-chloromethylketone (PPACK), apixaban, or Gly-Pro-Arg-Pro to inhibit fibrin. Reaction-diffusion simulations predicted 108 nM thrombin within the clot. Heparin addition to the start/stop assay had little effect on fibrin-bound thrombin, whereas addition of heparin-antithrombin (AT) required over 6 min to inhibit the thrombin, indicating a substantial diffusion limitation. In contrast, heparin-AT rapidly inhibited thrombin within microfluidic plasma clots, indicating marked differences in fibrin structure and functionality between plasma clots and whole blood clots. Addition of GPVI-Fab to blood before venous or arterial clotting (200 or 1000 s-1) markedly reduced fibrin-bound thrombin, whereas GPVI-Fab addition after 90 s of clotting had no effect. Perfusion of AF647-fibrinogen over washed fluorescein isothiocyanate (FITC)-fibrin clots resulted in an intense red layer around, but not within, the original FITC-fibrin. Similarly, introduction of plasma/AF647-fibrinogen generated substantial red fibrin masses that did not penetrate the original green clots, demonstrating that fibrin cannot be re-clotted with fibrinogen. Overall, thrombin within fibrin is non-elutable, easily accessed by peptides, slowly accessed by average-sized proteins (heparin/AT), and not accessible to fresh fibrinogen.

SUBMITTER: Crossen J 

PROVIDER: S-EPMC9989883 | biostudies-literature | 2023 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Investigating thrombin-loaded fibrin in whole blood clot microfluidic assay via fluorogenic peptide.

Crossen Jennifer J   Shankar Kaushik N KN   Diamond Scott L SL  

Biophysical journal 20230112 4


During clotting under flow, thrombin rapidly generates fibrin, whereas fibrin potently sequesters thrombin. This co-regulation was studied using microfluidic whole blood clotting on collagen/tissue factor, followed by buffer wash, and a start/stop cycling flow assay using the thrombin fluorogenic substrate, Boc-Val-Pro-Arg-AMC. After 3 min of clotting (100 s<sup>-1</sup>) and 5 min of buffer wash, non-elutable thrombin activity was easily detected during cycles of flow cessation. Non-elutable th  ...[more]

Similar Datasets

| S-EPMC6301986 | biostudies-literature
| S-EPMC12478570 | biostudies-literature
| S-EPMC3675619 | biostudies-literature
| S-EPMC8510862 | biostudies-literature
| S-EPMC2556616 | biostudies-literature
| S-EPMC5766256 | biostudies-literature
2025-08-15 | PXD062688 | Pride
| S-EPMC3678671 | biostudies-literature