Measurement of extended half-life recombinant FVIII molecules: In vitro and ex vivo evidence of relevant assay discrepancies.


ABSTRACT:

Background

Extended half-life recombinant FVIII products (EHL-rFVIIIs) have been engineered to improve the pharmacokinetic profile of FVIII, enabling better hemostatic protection with a reduced number of injections in persons with hemophilia. Previous studies showed several discrepancies in FVIII activity (FVIII:C) measurements for EHL-rFVIIIs comparing one-stage clotting assay (OSA) and chromogenic assay (CSA), although a systematic investigation of this phenomenon is still lacking.

Objective

Evaluation of the accuracy and precision of measurement of all available EHL-rFVIIIs with 5 different assays both in vitro and ex vivo.

Methods

Damoctocog alfa pegol, rurioctocog alfa pegol, turoctocog alfa pegol, and efmoroctocog alfa were tested with 3 OSA types: (1) aPTT-based commercial reagents with colloidal silica (Synthasil, Werfen-IL); (2) ellagic acid, Synthafax (Werfen-IL); and (3) OSA calibrated with each EHL-rFVIII product and colloidal silica. Measurements were also carried out with 2 different commercially available CSA reagents (Coamatic Factor VIII, Chromogenix-Werfen) and Trinichrom FVIII (Tcoag-Stago). A Bland-Altman analysis was performed to compare all assays.

Results

The simple OSA showed significant discrepancies between the expected and measured EHL-rFVIII concentrations as CSA methods, whereas the calibrated OSA assay was accurate and precise in determining the activity of all EHL-rFVIIIs in the in vitro setting. Comparable results were found using ex vivo plasma samples.

Conclusion

In this study, only OSA with a calibration curve constructed with each EHL-rFVIII product showed acceptable accuracy and precision in EHL-rFVIIIs measurements.

SUBMITTER: Lancellotti S 

PROVIDER: S-EPMC9999201 | biostudies-literature | 2023 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Measurement of extended half-life recombinant FVIII molecules: <i>In vitro</i> and <i>ex vivo</i> evidence of relevant assay discrepancies.

Lancellotti Stefano S   Sacco Monica M   Tardugno Maira M   Mancuso Maria Elisa ME   De Cristofaro Raimondo R  

Research and practice in thrombosis and haemostasis 20230210 2


<h4>Background</h4>Extended half-life recombinant FVIII products (EHL-rFVIIIs) have been engineered to improve the pharmacokinetic profile of FVIII, enabling better hemostatic protection with a reduced number of injections in persons with hemophilia. Previous studies showed several discrepancies in FVIII activity (FVIII:C) measurements for EHL-rFVIIIs comparing one-stage clotting assay (OSA) and chromogenic assay (CSA), although a systematic investigation of this phenomenon is still lacking.<h4>  ...[more]

Similar Datasets

| S-EPMC6118640 | biostudies-literature