Surgical Approach May Influence Survival of Large-Diameter Head Metal-on-Metal Total Hip Arthroplasty: A 6- to 10-Year Follow-Up Study.
Ontology highlight
ABSTRACT: Large-diameter head (LDH) metal-on-metal (MoM) total hip arthroplasty (THA) has lost popularity because of metal allergy or ALTRs (adverse local tissue reactions) in the past decade. Whether the surgical approach may influence the survival of LDH-MoM-THA has not been reported. From 2006 to 2009, we performed 96 LDH-MoM-THAs on 80 patients using an in situ head-neck assembly technique through a modified Watson-Jones approach. With a mean follow-up of 8.4 years (range, 6.3-10.1 years), the implant survival rate was 100%. All patients were satisfied with the results and the Harris Hip Score improved from 52 points to 98 points. No ALTRs were found, but 17.7% of the 96 hips (17 adverse events) experienced adverse events related to the cup, including 5 cases of outlier cup malposition, 11 cases of inadequate cup seating, and 1 acetabular fracture. The tissue tension that was improved by a muscle-sparing approach might lessen the chance of microseparation or edge-loading that is taken as the major risk for early implant failure. Further investigation of whether these LDH-MoM-THAs would fail or not would require a longer follow-up or even retrieval analysis in the future.
Project description:BackgroundIt is unclear whether a connection exists between femoral head size, offset, neck length, and cup abduction angles, and rate of revision in metal-on-metal (MoM) total hip arthroplasty (THA) implant systems.MethodsA retrospective review of MoM THA completed by a single surgeon with a single implant between 2003 and 2008 was conducted. Patient demographics, implant data, radiographs, and revision details were collected at follow-up. Incidence rates for revision and osteolysis were calculated in regard to the femoral head size, stem offset, neck length, and cup abduction angles.ResultsSix hundred and ninety two THAs were identified, with 79% of patients returning for a median follow-up of 10.3 years (interquartile range = 6.0-12.3). The median time to revision was 7.5 years (interquartile range = 5.3-9.9) among 27 total revision surgeries. The overall incidence rate of revision was 5.4 revisions per 1000 person-years, 3.0 revisions per 1000 person-years for adverse local tissue reaction. Hips with a cup abduction angle of ≤40° had revisions at nearly twice the rate of those with an angle of 41°-50° (incidence rate ratio = 1.98, 95% confidence interval: 0.92, 4.29). Hips with a 9 mm neck length had an increased rate of revision (incidence rate ratio = 5.94, 95% confidence interval: 1.33, 26.55) relative to those with a neck length of 0 mm. Rates of osteolysis were similar between implants of different head sizes, neck lengths and cup abduction angles.ConclusionsMoM implant systems with longer necks and smaller cup abduction angles may lead to increased need for revision. Results from this study suggest a need for closer long-term follow-up of MoM THA systems.
Project description:Massive allograft can be a useful option in revision total joint arthroplasty for treatment of significant bone loss. In rare cases, revision hip and knee arthroplasty procedures can be performed simultaneously using massive allograft-prosthetic composites. We present an 18 year follow up of a patient who received a simultaneous revision hip and knee total femoral allograft and discuss recent literature as it relates to this case.
Project description:Total hip arthroplasty (THA) has become one of the most reliable and patient-requested surgical interventions in all medicine. The procedure can be performed using a variety of surgical approaches, but the posterior approach, direct lateral approach, and direct anterior approach are by far the most common across the globe. This article highlights the history and technique for each of these common approaches. A review of outcomes and complications for each approach are also provided. Each approach has its own unique advantages and disadvantages, but all can be safely and successful utilized for THA. Strong, convincing, high-quality studies comparing the different approaches are lacking at this time. Surgeons are therefore recommended to choose whichever approach they are most comfortable and experienced using. Though not described here, THA can also be done using the anterolateral approach (also known as the Watson Jones approach) as well as the two-incision approach. In addition, recently, some surgeons are utilizing the so-called direct superior approach for THA. While these approaches are far less commonly utilized, they are recognized as viable alternatives to traditional approaches.
Project description:Taper corrosion of the head-neck junction is a potentially significant and devastating problem facing orthopedic surgeons. We present a case of a 53 year old male who presented for routine follow up for a left, large head, metal on metal total hip arthroplasty five years out. The patient was asymptomatic at the visit. X-rays at the time demonstrated a large amount of medial calcar osteolysis. Serum ion levels revealed a mildly increased cobalt and normal chromium level and hip aspiration revealed brownish fluid. At the time of revision surgery, corrosion of the head-neck taper was found with a normal appearing bearing surface leading to the diagnosis of mechanically assisted crevice corrosion of the head-neck taper with medial calcar osteolysis.
Project description:BackgroundThe mechanism of failure of metal-on-metal (MoM) total hip arthroplasty (THA) has been related to a high rate of metal wear debris, which is partly generated from the head-trunnion interface. However, it is not known whether implant fixation is affected by metal wear debris.Patients and methods49 cases of MoM THA in 41 patients (10 women) with a mean age of 52 (28-68) years were followed with stereoradiographs after surgery and at 1, 2, and 5 years to analyze implant migration by radiostereometric analysis (RSA). Patients also participated in a 5- to 7-year follow-up with measurement of serum metal ions, questionnaires (Oxford hip score (OHS) and Harris hip score (HHS)), and measurement of cup and stem positions and systemic bone mineral density.ResultsAt 1-2 years, mean total translation (TT) was 0.04 mm (95% CI: -0.07 to 0.14; p = 0.5) for the stems; at 2-5 years, mean TT was 0.13 mm (95% CI: -0.25 to -0.01; p = 0.03), but within the precision limit of the method. For the cups, there was no statistically significant TT or total rotation (TR) at 1-2 and 2-5 years. At 2-5 years, we found 4 cups and 5 stems with TT migrations exceeding the precision limit of the method. There was an association between cup migration and total OHS < 40 (4 patients, 4 hips; p = 0.04), but there were no statistically significant associations between cup or stem migration and T-scores < -1 (n = 10), cup and stem positions, or elevated serum metal ion levels (> 7µg/L (4 patients, 6 hips)).InterpretationMost cups and stems were well-fixed at 1-5 years. However, at 2-5 years, 4 cups and 5 stems had TT migrations above the precision limits, but these patients had serum metal ion levels similar to those of patients without measurable migrations, and they were pain-free. Patients with serum metal ion levels > 7 µg/L had migrations similar to those in patients with serum metal ion levels < 7 µg/L. Metal wear debris does not appear to influence the fixation of hip components in large-head MoM articulations at medium-term follow-up.
Project description:PurposeLocal infiltration analgesia (LIA) is commonly used for postoperative pain management following total hip arthroplasty (THA). However, the long-term effects of the component drugs are unclear. The aim of our study was to investigate functional outcome, quality of life, chronic post-surgical pain, and adverse events in patients within 2 years of undergoing THA.MethodsThe study was a secondary analysis of data from a previous larger study. Eighty patients were randomized to receive either intrathecal morphine (Group ITM) or local infiltration analgesia (Group LIA) for pain management in a double-blind study. The parameters measured were patient-assessed functional outcome [using the Hip dysfunction and Osteo-arthritis Outcome Score (HOOS) questionnaire], health-related quality of life [using the European Quality of Life-5 dimensions (EQ-5D) questionnaire and the 36-Item Short Form Health Survey (SF-36) score], and pain using the numeric rating score (NRS), with persistent post-surgical pain having a NRS of > 3 or a HOOS pain sub-score of > 30. All complications and adverse events were investigated during the first 2 years after primary surgery.ResultsPain intensity and rescue analgesic consumption were similar between the groups after hospital discharge. No differences were found in HOOS or SF-36 score between the groups up to 6 months after surgery. A significant group × time interaction was seen in the EQ 5D form in favor of the LIA group. No between-group difference in persistent post-surgical pain was found at 3 or 6 months, or in adverse events up to 2 years after surgery.ConclusionAnalysis of functional outcome, quality of life, and post-discharge surgical pain did not reveal significant differences between patients receiving LIA and those receiving ITM. LIA was found to be a safe technique for THA during the long-term follow-up. However, it should be noted that these conclusions are based on a limited number of patients.
Project description:Metal-on-metal (MoM) arthroplasty systems became popular in the early-2000s due to presumed advantages of improved wear characteristics and superior stability. However, subsequent reports of abnormal soft-tissue reactions to MoM implants and national registry data reporting high failure rates raised concerns. Early outcomes of revision total hip arthroplasty (THA) for adverse reaction to metal debris (ARMD) were poor, leading to development of surveillance programs and a trend towards early revision surgery. Patients with MoM arthroplasties require surveillance, comprehensive history and physical examination, imaging with ultrasound or magnetic resonance imaging (MRI), and laboratory evaluation including metal ion levels. Operative strategies for revision THA vary from exchange of modular components to extensive debridement and reconstruction with revision components. Surgeons should be aware of the increased risks of dislocation and infection following revision THA for ARMD. However, there is growing evidence that early revision surgery prior to extensive soft tissue destruction results in improved outcomes and decreased re-operation rates. It is estimated that >1 million MoM articulations have been implanted, with a large proportion still in situ. It is imperative to understand the aetiology, presentation, and management strategies for these patients to optimise their clinical outcomes.
Project description:ImportanceThere are concerns about increased mortality in patients with metal-on-metal bearings in total hip arthroplasty (THA).ObjectiveTo determine the mortality and the morbidity in patients with metal-on-metal articulations (MOM THA) compared to patients with non-metal-on-metal articulations (non-MOM THA) after primary total hip arthroplasty.Data sourcesSearch of PubMed, MEDLINE, EMBASE, Web of Science, Cochrane, CINAHL, AcademicSearchPremier, ScienceDirect, Wiley and clinical trial registers through March 2015, augmented by a hand search of references from the included articles. No language restrictions were applied.Study selectionTwo reviewers screened and identified randomised controlled trials and observational studies of primary total hip arthroplasty comparing MOM THA with non-MOM THA.Data extraction and synthesisTwo reviewers independently extracted study data and assessed risk of bias. Risk differences (RD) were calculated with random effect models. Meta-regression was used to explore modifying factors.Main outcomes and measuresDifference in mortality and difference in morbidity expressed as revisions and medical complications between patients with MOM THA and non-MOM THA.ResultsForty-seven studies were included, comprising 4,000 THA in randomised trials and over 500,000 THA in observational studies. For mortality, random effects analysis revealed a higher pooled RD of 0.7%, 95%, confidence interval (CI) [0.0%, 2.3%], I-square 42%; the heterogeneity was explained by differences in follow-up. When restricted to studies with long term follow-up (i.e. 10 years or more), the RD for mortality was 8.5%, 95%, CI [5.8%, 11.2%]; number needed to treat was 12. Further subgroup analyses and meta-regression random effects models revealed no evidence for other moderator variables (study level covariates, e.g. resurfacing vs. non-resurfacing MOM) than follow-up duration. The quality of the evidence presented in this meta-analysis was characterized as moderate according to the CLEAR-NPT (for non-pharmacological trials) and Cochrane risk of bias Table.Conclusions and relevanceMeta-analysis suggests there may be an increased long-term risk of mortality and revision surgery for patients with MOM THA compared to patients with non-MOM THA.RegistrationPROSPERO 2014:CRD42014007417.
Project description:We previously reported on the metal ion concentrations of cobalt, chromium, and titanium that were found in the serum of patients three years after they had undergone primary total hip arthroplasty as compared with the concentrations found in the serum of control patients who did not have an implant. This study is a concise update on the serum metal levels found in a cohort of these patients ten years after the time of hip implantation. Of the original seventy-five subjects, metal ion levels were available for forty patients (53%). Ten patients (hybrid group) had received a hybrid total hip replacement that consisted of a modular cobalt-alloy femoral stem with a cobalt-alloy femoral head that had been inserted with cement and a titanium acetabular socket that had been inserted without cement. Nine patients (cobalt-chromium [CoCr] group) had received an implant with an extensively porous-coated modular cobalt-alloy femoral stem and femoral head along with a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Eight patients (titanium group) had undergone insertion of a proximally porous-coated modular titanium-alloy femoral stem with a cobalt-alloy femoral head and a titanium acetabular socket; the femoral and acetabular components had each been inserted without cement. Thirteen patients (control group) from the original control group of patients who had not received an implant served as control subjects. Serum metal levels were measured with use of high-resolution sector field inductively coupled plasma mass spectrometry. The hybrid total hip arthroplasty group had mean cobalt levels that were 3.2 times higher at 120 months than they were at baseline, and the cobalt levels in that group were significantly higher than those in the titanium total hip arthroplasty group at thirty-six, sixty, eighty-four, ninety-six, and 120 months (p < 0.01). The hybrid group had mean chromium levels that were 3.9 times higher at 120 months than they were at baseline, and the CoCr total hip arthroplasty group had chromium levels that were 3.6 times higher at 120 months than they were at baseline. The serum titanium levels were higher in the titanium group at all follow-up time intervals as compared with the levels in all other groups, and the level in the titanium group at 120 months was eighteen times higher than it was at baseline (p < 0.01). Patients with well-functioning primary metal-on-polyethylene total hip replacements had elevated serum metal levels for as many as ten years postoperatively. Furthermore, metal release at the modular femoral head-neck junctions, rather than passive dissolution from porous ingrowth surfaces, was likely the dominant source of serum cobalt and chromium.
Project description:The increasing demand for total hip arthroplasty (THA) in relatively young, high-demand patients has led to the use of hard-on-hard bearing surfaces. Adverse local tissue reaction/pseudotumor and elevated serum metal ion levels are commonly reported complications encountered in metal-on-metal THA, while audible articulation and rim fracture are reported in ceramic-on-ceramic THA. For this reason, ceramic-on-metal THA was implemented as an ideal hard-on-hard bearing combination. In this report, we describe a case of bilateral simultaneous ceramic-on-metal THA in a 69-year-old woman who presented 7 years postoperatively with unilateral hip pain associated with underlying pseudotumor and elevated serum cobalt and chromium ion levels. Pre-revision workup, intraoperative findings, and postoperative evaluation are included and suggest acetabular malposition as a potential source for complication.